| Coaxial Cables | ||||||||||||
M17/2-RG 6 (RG 6 A/U)
Construction

| Inner conductor | Coppercladsteel(CCS) | Φ0.72±0.025mm |
|---|---|---|
| Dielectric | LowdensityPE | Φ4.70±0.10mm |
| Outer conductor(shield1) | Silverplatedcopper | 144x0.16mm |
| Shield coverage | 97% | |
| Outer conductor(shield2) | Plaincopper | 144x0.16mm |
| Shield coverage | 95% | |
| Sheath | PVCorLSZH | Φ8.50±0.10mm |
Electrical & Mechanical Characteristics
Impedance :75±5Ohm
Nominal capacitance :67pF/m
Velocity of propagation :66%
Insulation resistance :>2000Mohm.Km
Inner conductor resistance :106Ohm/Km
Outer conductor resistance :5.0Ohm/Km
Test/Operatig Voltage(max) :5.0KV/3.0KV
Operating temperature range :-30°C-+70°C
Copper weight :46Kg/Km
Cable weight(approx.) :64.6Kg/Km
Screening effectiveness :>70dB
Attenuation
| Frequency(MHz) | Attenuation(dB/100m) | Attenuation(dB/100ft) |
|---|---|---|
| 50 | 5.8 | 1.77 |
| 100 | 8.5 | 2.59 |
| 200 | 12.5 | 3.81 |
| 400 | 18 | 5.49 |
| 500 | 20.3 | 6.19 |
| 600 | 22.6 | 6.89 |
| 860 | 27.5 | 8.38 |
| 1000 | 30.4 | 9.27 |
Return Loss
| 30-300MHz | >28dB |
|---|---|
| 300-600MHz | >24dB |
| 600-900MHz | >22dB |